Common array manager - クイックスタートガイド. このマニュアルでは、オラクルの Sun Storage Common Array Manager ソフトウェアをインストールする基本的な手順について説明します。. 以前のバージョンからアップグレードする場合、または追加情報が必要な場合は、『Sun Storage Common ...

 
 The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. . Google not for profit

viSun StorageTek Common Array Manager 软件安装指南• 2008 年 10 月. 查找文件和日志 11 安装命令汇总 13 从远程终端安装(Solaris 和 Linux) 13 在 Solaris OS 上安装 14 在 Solaris OS 上使用 GUI 进行安装 14. 安装软件(在 Solaris 系统上):15 在 Solaris OS 上使用 CLI 进行安装 19. 使用 ... Feb 21, 2023 · This article documents Sun Storage 2540-M2 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of verifying component ... “Related Documentation” on page vi for a list of array installation document titles. Related Documentation TABLE P-1 provides a list of documents related to the Sun Storage Common Array Manager software. TABLE P-1 Related Documentation Application Title Latest information Sun Storage Common Array Manager Software Release Notes Sun StorageTek Common Array Manager 软件发行说明 3 发行文档 以下是 Sun StorageTek Common Array Manager 的相关文档列表。对于文件号码中带 有 nn 后缀的文档,请使用其最新版本。 此外,Common Array Manager 软件还包含有关 CLI 命令的联机帮助和手册页。 The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. E-mail alert notification The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring.The Sun StorageTek[TM] Common Array Manager (CAM) has the ability to collect support based configuration and logs for Sun StorEdge[TM], Sun StorageTek [TM], StorageTek[TM], Sun Storage[TM] Arrays. This can be performed using the Browser or CLI interface. The purpose of this document is to describe how to collect this information.Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options …This chapter describes performing general administrative tasks applicable to all arrays. It contains the following subsections: “Using the Browser Interface” on page 2 “Administering Storage Arrays” on page 11 “Administering User Accounts” on page 17. 1. Using the Browser InterfaceThis article documents Sun StorageTek Flexline 380 (FLX380) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support …1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet n.n.n.n. 3. After logging in, switch user … vi Sun StorageTek Common Array Manager ユーザーズガイドオープンシステム用• 2010 年 2 月 FMS エージェントの構成 65 アレイの健全性の監視の有効化 67 アラームとイベントの監視 67 アラーム情報の表示 68 アラームの管理 70 アラームの承認 70 1 つまたは複数のアラーム ... Dell OpenManage Array Manager, v.3.6.0.568.5, A05. Array Manager software provides a comprehensive storage management solution in an integrated, graphical view. From a single location, Array Manager enables you to configure and manage local and remote storage attached to a server, while the server is online and continuing to process requests.Sun Storage Common Array Manager (CAM) - Version 6.1 to 6.10 [Release 6.0]: Sun Storage Common Array Manager (CAM): Connections Refused with Error "ERR_SSL_WEAK_SERThis document describes a possible problem in Sun Storage Common Array Manager (CAM) version 6.9.0.20 on Solaris that can prevent registration of arrays. CAM 6.9.0.20 involves the installation of CAM 6.9 and then the addition of either <Patch 147416-02> (Solaris SPARC) or <Patch 147419-02> (Solaris x86). Array registration in …The Sun StorageTek Common Array Manager CLI Guide for Release 6.2 describes the commands in the sscs CLI. Sun StorageTek Common Array Manager CLI Guide, Release 6.2.0 C H A P T E R 1: Overview This chapter provides an overview of the sscs administration command for Sun StorageTek and Sun Storage arrays. It contains the … Sun StorageTek Common Array Manager 软件发行说明 3 发行文档 以下是 Sun StorageTek Common Array Manager 的相关文档列表。对于文件号码中带 有 nn 后缀的文档,请使用其最新版本。 此外,Common Array Manager 软件还包含有关 CLI 命令的联机帮助和手册页。 Sun Storage Common Array Manager Software Release Notes, Release 6.9.0 Update December 2012. Review important late-breaking information about Sun Storage Common Array Manager.Jan 1, 2023 · Common Array Manager alarm code xx.66.1040: A controller cache backup battery has failed. Refer to <Document 1021057.1> Sun Storage Common Array Manager (CAM): How to Verify Critical Faults for Sun Storage 2500, 2500-M2, 6000 and J4000 Arrays. Changes. No changes have occurred on the array, other than the automated Learn Cycle has been run. Cause This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training forSun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed. Sun Storage Common Array Manager Array Baseline Firmware Reference, Version 6.10 (English) l Review the latest array baseline firmware versions delivered with Oracle's Sun Storage Common Array Manager 6.10. Download. Sun Storage Common Array Manager Quick Start Guide (English) l This guide can help you with the basic steps of installing Oracle ... Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.Sun Storage Common Array Manager (CAM) - Version 5.0 and later Information in this document applies to any platform. Symptoms. Common Array Manager (CAM) is generating an alarm for a fault against one of its registered arrays. CAM fails to report the appropriate description and grid code for the alarm. The details may look …Storage Common Array Manager 6.8.1. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays19. Choose Typical to install the full management software on the data host. 10. Click next to display the Review Selections Screen. The screen should show that the software to be installed is the Full Install. The …Documentation. For hardware information, refer to the array's release notes and hardware installation guide. Online help and man pages are incorporated into the Sun Storage Common Array Manager software. OUTPUT. Sun Storage Common Array Manager Software Release Notes Release 6.10 for Solaris OS Host l. Review important late-breaking information about Sun Storage Common Array Manager 6.10. Download. Sun Storage Common Array Manager Version: 6.10.0 Third Party License README l. This Third Party License README document applies to Sun Storage ... Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. Instead customers typically do remote scripting using the remote CLI … Sun StorageTek Common Array Manager The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is installed on a management host cabled to the array via out-of-band Ethernet (cables for this connection are provided). To obtain a general ... Instructions to download Common Array Manager (CAM). Log in to My Oracle Support. Click on the "Patches & Updates" tab on the top bar. In the "Patch Name or Number" field, enter the patch number (ie: 10272123 or 141474-01) corresponding to the CAM software or patch you want to download. Click on "Search". Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options … Sun StorageTek Common Array Manager The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is installed on a management host cabled to the array via out-of-band Ethernet (cables for this connection are provided). To obtain a general ... Select the array. Select Administration -> Manage Passwords -> Update Array Password in Array Registration Database. Leave the "New Password" and "Verify New Password" fields blank. To remove the array password on a 6130 running a firmware lower than 06.19.23.10, you can use the "clrpw" utility available here.Multiple array management<br /> Remote Proxy<br /> The remote proxy agent enables communication, equivalent to in-band management,<br /> from the full management host to the array over an out-of-band-band IP network.<br />This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training for1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user … Ce document est destiné à vous guider dans les étapes de base de l’installation du logiciel Sun Storage Common Array Manager d’Oracle. Si vous procédez à une mise à niveau à partir d’une ancienne version ou souhaitez obtenir des informations complémentaires, consultez le Sun Storage Common Array ManagerGuide d’installation et de ... 2 Sun Storage Common Array Manager Software 6.8.1 Release Notes • September 2011 About the Software Sun Storage Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor storage arrays. The software includes a distributed architecture enabling you to designate local and Oracle’s Sun Storage Common Array Manager includes the following documentation integrated within the software: Sun Storage Common Array Manager online help Available via the “Help” button within the Sun Storage Common Array Manager browser interface. Service Advisor Provides guided, FRU-replacement procedures with system feedback for all Apr 3, 2023 · Sun Storage Common Array Manager (CAM) has the ability to collect support-based configuration and logs for Sun Storage 2500, 2500-M2, J4000, F5100, 6000 and Flexline Arrays. This can be performed using the Browser or CLI interface. The purpose of this document is to describe how to collect this information. If you are using a Sun Storage J4000 ... Storage Common Array Manager 6.9.0. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays1Goal. This article documents Sun Storage 2540-M2 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. …Goal. If you want to install Sun Storage Common Array Manager (CAM) in a Solaris 10 non-global zone, you first need to install Lockhart/Java Web Console in the Solaris 10 global zone, otherwise the installation of CAM fails with one or more of the following errors:Sun Storage Common Array Manager Installation and Setup Guide Administration, configuration, and monitoring Online help integrated with the software. Customer and field replacement procedures Service Advisor integrated with the software. Reference information for the CLI Sun Storage Common Array Manager CLI Guide sscsman pages1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet n.n.n.n. 3. After logging in, switch user …This URL seems to be what you want: Installing the Typical Full Management Software. But having said that - you may want to look at a newer and more supported product. On Oracle Support I can not download the software without support for the Unit. They also don’t want to sell support / the software for the Unit. To Assign an IP Address to Each Ethernet Port. . Access the Sun StorageTek Common Array Manager software: Open a web browser and enter the IP address of the management host: https://management-host:6789. management-host is the IP address of the machine where you installed the management software. Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest. Sun Storage Common Array Manager (CAM) - Version 6.0 and later Sun Storage Flexline 280 Array - Version Not Applicable and later All Platforms Goal. This article documents Sun StorageTek Flexline 280 (FLX280) Array's components firmware baseline bundled in each corresponding CAM release and patched versions.Category filter: Show All (183)Most Common (3)Technology (42)Government & Military (46)Science & Medicine (41)Business (40)Organizations (52)Slang / Jargon (5) Acronym Definition CAM Camera CAM Computer-Aided Manufacturing CAM Camshaft CAM 7 CAM Camcorder (video source) CAM Complementary and Alternative Medicine CAM Camden … 通过打开浏览器并输入下列地址,从主阵列管理服务器登录 Sun Storage Common Array Manager: https://host-name:6789. 其中,host-name 为连接到该阵列的服务器的 DNS 名称。. 在“存储系统摘要”页面中,单击“注册”并按照向导中的说明将该阵列注册到第一个服务器的 IP 地址 ... Category filter: Show All (183)Most Common (3)Technology (42)Government & Military (46)Science & Medicine (41)Business (40)Organizations (52)Slang / Jargon (5) Acronym Definition CAM Camera CAM Computer-Aided Manufacturing CAM Camshaft CAM 7 CAM Camcorder (video source) CAM Complementary and Alternative Medicine CAM Camden …“Related Documentation” on page vi for a list of array installation document titles. Related Documentation TABLE P-1 provides a list of documents related to the Sun Storage Common Array Manager software. TABLE P-1 Related Documentation Application Title Latest information Sun Storage Common Array Manager Software Release NotesSun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. There are several components of the Sun StorageTek[TM] Common Array Manager (CAM) software : Solaris Web Console(SWC) Browser/Remote sscs interface(BUI/CLI) Fault Management Service(FMS)The Program calculates the sets, rises and phases of the sun and moon... The HPE Smart Storage Administrator (HPE SSA) is a web-based application... Trusted Windows (PC) download Sun Storage Common Array Manager Online Help 6.9.0.16. Virus-free and 100% clean download. Sun StorageTekTM Common Array Manager CLI Quick Reference. This document lists the sscs(1M) subcommands that you can use to administer the Sun StorageTekTM 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and 380 Systems from the command-line interface (CLI).For the Sun Storage J4000 Array Family, refer to the Sun StorageTek Common ... vi Sun StorageTek Common Array Manager User Guide for the J4000 Array Family • August 2008 The Event Life-Cycle 67 Setting Up Notification for Fault Management 68 Configuring Array Health Monitoring 76 To Configure the FMS Agent 76 To Enable Health Monitoring for an Array 78 Monitoring Alarms and Events 80It is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400). Sun StorageTek Common Array Manager 软件发行说明 3 发行文档 以下是 Sun StorageTek Common Array Manager 的相关文档列表。对于文件号码中带 有 nn 后缀的文档,请使用其最新版本。 此外,Common Array Manager 软件还包含有关 CLI 命令的联机帮助和手册页。 ——————————————————————————-Sun Storage Common Array Manager 6.8.1 Please read the following license agreement carefully. Oracle has acquired Sun Microsystems, Inc. (“Sun”), you acknowledge that in all cases where the reference is Sun, Oracle will fulfill these obligations as successor in ...Select the array. Select Administration -> Manage Passwords -> Update Array Password in Array Registration Database. Leave the "New Password" and "Verify New Password" fields blank. To remove the array password on a 6130 running a firmware lower than 06.19.23.10, you can use the "clrpw" utility available here.vi Sun StorageTek Common Array Manager Software Installation Guide • October 2006 Creating Initiators to Assign to Hosts 61 To Create An Initiator and Assign It To a Host: 61 Using the New Volume Wizard to Create and Map Volumes 62 To Use the New Volume Wizard to Create Volumes 62 About Volumes and the Default Domain or Partitioned …Support data for an array is collected and saved in the Common Array Manager by selecting array > General Configuration > Support Data. On the Windows 2008 server, disable “Do not save encrypted pages to disk.” Go to Tools > Internet Options > Advanced > Security and uncheck "Do not save encrypted pages to disk." Linux platformsThe SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring.See your Sun StorageTek Common Array Manager Software Installation Guide (part number 820-4193) or Sun StorageTek Common Array Manager User Guide for the J4000 Array Family (part number 820-3765). 5. Log in as root (Solaris and Linux) or as a user with administrator privilege (Windows) on the management host. 6. viSun StorageTek Common Array Manager 软件安装指南• 2008 年 10 月. 查找文件和日志 11 安装命令汇总 13 从远程终端安装(Solaris 和 Linux) 13 在 Solaris OS 上安装 14 在 Solaris OS 上使用 GUI 进行安装 14. 安装软件(在 Solaris 系统上):15 在 Solaris OS 上使用 CLI 进行安装 19. 使用 ... The Sun StorageTek [TM] Common Array Manager (CAM) has the ability to collect support based configuration and logs for Sun StorEdge [TM], Sun StorageTek [TM], StorageTek …Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options …From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page.Category filter: Show All (183)Most Common (3)Technology (42)Government & Military (46)Science & Medicine (41)Business (40)Organizations (52)Slang / Jargon (5) Acronym Definition CAM Camera CAM Computer-Aided Manufacturing CAM Camshaft CAM 7 CAM Camcorder (video source) CAM Complementary and Alternative Medicine CAM Camden …Chapter 1 Sun Storage Common Array Manager Software Release Notes. Use this document for instructions about how to download the latest Oracle's Sun Storage Common Array Manager software and learn about new features, related documentation, system requirements, notable bug fixes, and known issues for the CAM 6.9.0 product release.Sun StorageTek Array Administration Guide, Version 6.5.0. PDF. Sun StorageTek Common Array Manager User Guide for Open Systems. HTML. PDF. Sun StorageTek Common Array Manager CLI Guide, Version 6.5.0. HTML. PDF. Sun StorageTek Common Array Manager Software 6.5 Product Library Documentation. Sun Storage Common Array Manager Quick Start Guide, Version 6.8.x This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see the Sun Storage Common Array Manager Software Installation and Setup Guide. Ce document est destiné à vous guider dans les étapes de base de l’installation du logiciel Sun Storage Common Array Manager d’Oracle. Si vous procédez à une mise à niveau à partir d’une ancienne version ou souhaitez obtenir des informations complémentaires, consultez le Sun Storage Common Array ManagerGuide d’installation et de ... Sun StorageTek Common Array Manager Software Installation Guide, Version 6.5.0: HTML: PDF: Sun StorageTek Array Administration Guide, Version 6.6.0: PDF: Sun StorageTek Common Array Manager User Guide for Open Systems: HTML: PDF: Sun StorageTek Common Array Manager CLI Guide, Version 6.6.0: HTML: PDF: Sun …1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user …iv Sun StorageTek Common Array Manager CLI Guide • September 2009 Commands Used 21 Sample Data 21 Command Sequence 21 3. Monitoring and Administration Commands for All Arrays 27 add notification 27 Synopsis 27 Description 28 Options 28 Examples 29 add registeredarray 29 Synopsis 29 Description 29 Options 30 Examples 30The Sun StorageTek Common Array Manager software is a web-based management software that provides both a browser interface and a command-line interface (CLI) for …1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user …Common Array Manager Windows 7 Pro, CAM ver 6.9.0.16. Not sure, this might an appropriate forum for this question. I am afraid this question bears no relation to Oracle on Microsoft Windows - Installation, Configuration and Troubleshooting.Setting Up Notification for Fault Management. The fault management features of Sun Storage Common Array Manager enables you to monitor and diagnose your arrays and storage environment. Alarm notification can be provided by: Email notification Simple Network Management Protocol (SNMP) trapsThe SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring.

Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. . Printme.com

common array manager

Using the Disk Array Manager The Disk Array Manager is the interface for performing various tasks with disk arrays. Preparing disks for use in SAS disk arrays Use this information to prepare disks for use in an array. Secure data deletion for Array Candidate pdisks that are formatted to RAID block sizeThe Sun StorageTek Common Array Manager (CAM) software suite is your main tool for Sun Storage array enclosure management, monitoring, and service capabilities. The software has both a secure browser interface and a command-line interface (CLI). CAM is supported for use with Solaris, Linux and Windows platforms. Viewing Sun Storage … 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page. Sun Storage Common Array Manager Software Release Notes, Release 6.9.0 Update December 2012. Review important late-breaking information about Sun Storage Common Array Manager.How to Download Common Array Manager (CAM) Software and Patches [Doc ID 1296274.1] Note - Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM.It is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400).Storage Common Array Manager 6.10. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays1Overview of the sscs Command. The sscs command-line interface (CLI) enables you to manage and monitor disk arrays. The CLI can be installed on a local data host or a remote management host.. There are two forms of the CLI: Local CLI This is the version used in a CLI-only installation of Sun Storage Common Array Manager, and should be used if … Sun Storage Flexline 380 Array Sun Storage Common Array Manager (CAM) - Version: 5.0 and later [Release: 5.0 and later] Sun Storage 6180 Array - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun Storage 6780 Array - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Mar 9, 2022 · Goal. Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and stopping the JWC service is done when troubleshooting login problems, making JWC configuration changes, installing a JWC patch, or installing a legacy JWC application. Sun Storage Common Array Manager (CAM) - Version 6.9 to 6.10 [Release 6.0] Information in this document applies to any platform. Symptoms. When attempting to launch Service Advisor from Sun Storage Common Array Manager (CAM), the following message appears: "Service advisor package not installed for this type of device."It is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400).The Sun StorageTek Common Array Manager CLI Guide for Release 6.2 describes the commands in the sscs CLI. Sun StorageTek Common Array Manager CLI Guide, Release 6.2.0 C H A P T E R 1: Overview This chapter provides an overview of the sscs administration command for Sun StorageTek and Sun Storage arrays. It contains the …Sun Storage Common Array Manager (CAM) - Version 6.9 to 6.9 [Release 6.0] Information in this document applies to any platform. Purpose. The purpose of this document is to provide an easily accessible reference for the supported browsers and operating systems for Sun Storage Common Array Manager (CAM), version 6.9.Sun Storage Common Array Manager (CAM) - Version 5.0 and later Information in this document applies to any platform. Symptoms. Common Array Manager (CAM) is generating an alarm for a fault against one of its registered arrays. CAM fails to report the appropriate description and grid code for the alarm. The details may look …Applying Solaris patch 147416-02 (sparc) or patch 147419-02 (x86) to Sun Storage Common Array Manager (CAM) version 6.9.0 may cause registered arrays to present an alarm stating that out-of-band (oob) communication has been lost, and report the health status of the array as "Lost Communication".

Popular Topics